Is especially used for deep dehydration of natural gas in CNG gas filling station
The general technical parameters that can be meet by the deep dehydration device of natural gas
1.Model Low-pressure front, ultra low pressure front, large water content, super flow, high pressure postposition etc.
2. Equipment design working pressure range
3. Maximum handing ability6000Nm
3
/h(1.0mpa)
4. Working environment temperature -30 50°C
5 .Design temperature 345°C
6. Renewable heating temperature 210~230 °C
7. Product gas ordinary pressure dew point ≤-60°C
8.Maximum water content of raw material gas≤3500PPmv
9. Equipment overall pressure drop ≤0.03MPa
10.Adsorbent Molecular sieve
11.Regenerative method Built-in electric furnace, closed loop recycling
12.Cooling-down method Air-cooled or water cooled
13. Number of drying tower 2-4 tower
14.Class of explosive-proof dIIBT4
15. Level of protection IP64
16. Power requirements 380V±7%
17.Electric power around 40% smaller than other similar manufacturers
18.Control method Dedicated control cabinet, manual switching, automatic regeneration, manual discharge
19. Equipment noise ≤70 decibel
20.Measures to Ambient temperature is below 5 prevent ice block 5 °C heating band automatically
21.Fixed mode ship-shaped skid base, without to fix, easy to install
Descriptions of features and performance of equipment
1. Equipment imported the advanced technology from Italy and the United States, novel structure, easy operation, maintenance-free after commissioning. Using the 2 to 4 tower structure for the same equipment, single-stage adsorption, can handle high water content and large flows of feed gas, big quantity of adsorption, long cycle of adsorption, low depth of dehydration, can be operate continuously, continuous output of normal atmospheric dew point lower than -60°C purity, dry gas . Eliminate duplication investment of purchase multiple equipment.
2. The unique closed-loop recycling technology, built-in electric furnace, gas through the heater, flow of gas is slow, heating time is long, with high heating efficiency, heat evenly, small heat loss, to ensure full utilization of energy and greatly reduce the electric power and renewable energy, heater power is accompanied about 60% of other manufacturers. Electric furnace with constant temperature design, the entire regeneration process control at a constant heating temperature range, avoid the damage and loss of power of the electric furnace itself by frequent starting and stopping, effectively reducing the operating costs, extend equipment’s service life.
3. Vessel shell design, manufacture, testing, acceptance according to GB150 <Steel pressure vessels>, and the State Quality and Technical Supervision issued by the <Pressure Vessel Safety Technology supervision order>. Provide a full set of the required documentation of pressure vessels.
4. Original container and furnace design, ensuring smooth gas flow, bed stability, and elimination of damage to the container due to heating or cooling; absorption tower using 16 MnR material, resistant to fatigue, to run at low pressure, the container services for a more longer time.
5. Drying tower configured a filter can effectively remove the particulate component of natural gas , outlet with a fine filter, to prevent secondary pollution caused by adsorbent off, reducing the duplication process pipeline, reducing the pressure drop of equipment, saving the user’s investment cost.
6.This device is equipped with special cabinet, can accurately control the temperature when regenerating the device process, and in accordance with set procedures for movement control regeneration system; control panel set regenerate manual and automatic mode, and manually comes priority. When the regeneration is cycling, it can start or stop the heater, cooler at any time according to actual needs. Control procedures into the work order and interlocking relationships, to avoid human errors caused the losses. Based on the cooling fan, it has set up and down line running between temperature, to ensure the regeneration system does not over-temperature, regenerative heat exchanger does not ice block in winter, and the dew point temperature and dry gas can be observed.
7. For control system, except drying tower, switchover of regeneration tower need manual valve, all other actions will be automatically by the device. When the work tower is adsorbing, output dry gas; when regeneration tower is adsorbing, use a control valve to control the heating temperature of heater, when the regeneration has been finished, heater will automatically stop heating, start doing cold blow, when the temperature inside of the tower blow to the set temperature, the control cabinet will automatically stop all running power system, complete regeneration; all the control parameter can be remodify on controller, flexible and easy.
8. On drying tower device has set pressure gauge, temperature meter, visual display of work pressure and regeneration temperature and other working conditions; drying tower absorption tower has set discharge port with dedicated loading, easy replacement of filling.
9. Drying tower covered with high efficient insulation coating, good effect of insulation, beautiful looking.
10. Electric heating elements are using stainless steel material, thermal conductivity of large area, heating pipe with long service life,ensured that it’s working life will not less than 3 years.
11.Cooler adopts air-cooled efficient plate heat exchanger, it is 2500~4000 M
2
/M
3
higher than surface area. Compared with the same heat transfer area of the tube-fin heat exchanger, the volume was reduced 1.3 times, weight has reduced of more than 1 time.
12. Power generation location of device is reasonable, focus on external connection, produced according DIIBT4 explosion levels.
13.Galvanized pipe through the paint treatment, outdoor installation, long-term use does not fade.
Tuesday, October 25, 2011
Natural Gas Dehydration Unit For Cng Filling Station
Is especially used for deep dehydration of natural gas in CNG gas filling station
The general technical parameters that can be meet by the deep dehydration device of natural gas
1.Model Low-pressure front, ultra low pressure front, large water content, super flow, high pressure postposition etc.
2. Equipment design working pressure range
3. Maximum handing ability6000Nm
3
/h(1.0mpa)
4. Working environment temperature -30 50°C
5 .Design temperature 345°C
6. Renewable heating temperature 210~230 °C
7. Product gas ordinary pressure dew point ≤-60°C
8.Maximum water content of raw material gas≤3500PPmv
9. Equipment overall pressure drop ≤0.03MPa
10.Adsorbent Molecular sieve
11.Regenerative method Built-in electric furnace, closed loop recycling
12.Cooling-down method Air-cooled or water cooled
13. Number of drying tower 2-4 tower
14.Class of explosive-proof dIIBT4
15. Level of protection IP64
16. Power requirements 380V±7%
17.Electric power around 40% smaller than other similar manufacturers
18.Control method Dedicated control cabinet, manual switching, automatic regeneration, manual discharge
19. Equipment noise ≤70 decibel
20.Measures to Ambient temperature is below 5 prevent ice block 5 °C heating band automatically
21.Fixed mode ship-shaped skid base, without to fix, easy to install
Descriptions of features and performance of equipment
1. Equipment imported the advanced technology from Italy and the United States, novel structure, easy operation, maintenance-free after commissioning. Using the 2 to 4 tower structure for the same equipment, single-stage adsorption, can handle high water content and large flows of feed gas, big quantity of adsorption, long cycle of adsorption, low depth of dehydration, can be operate continuously, continuous output of normal atmospheric dew point lower than -60°C purity, dry gas . Eliminate duplication investment of purchase multiple equipment.
2. The unique closed-loop recycling technology, built-in electric furnace, gas through the heater, flow of gas is slow, heating time is long, with high heating efficiency, heat evenly, small heat loss, to ensure full utilization of energy and greatly reduce the electric power and renewable energy, heater power is accompanied about 60% of other manufacturers. Electric furnace with constant temperature design, the entire regeneration process control at a constant heating temperature range, avoid the damage and loss of power of the electric furnace itself by frequent starting and stopping, effectively reducing the operating costs, extend equipment’s service life.
3. Vessel shell design, manufacture, testing, acceptance according to GB150 <Steel pressure vessels>, and the State Quality and Technical Supervision issued by the <Pressure Vessel Safety Technology supervision order>. Provide a full set of the required documentation of pressure vessels.
4. Original container and furnace design, ensuring smooth gas flow, bed stability, and elimination of damage to the container due to heating or cooling; absorption tower using 16 MnR material, resistant to fatigue, to run at low pressure, the container services for a more longer time.
5. Drying tower configured a filter can effectively remove the particulate component of natural gas , outlet with a fine filter, to prevent secondary pollution caused by adsorbent off, reducing the duplication process pipeline, reducing the pressure drop of equipment, saving the user’s investment cost.
6.This device is equipped with special cabinet, can accurately control the temperature when regenerating the device process, and in accordance with set procedures for movement control regeneration system; control panel set regenerate manual and automatic mode, and manually comes priority. When the regeneration is cycling, it can start or stop the heater, cooler at any time according to actual needs. Control procedures into the work order and interlocking relationships, to avoid human errors caused the losses. Based on the cooling fan, it has set up and down line running between temperature, to ensure the regeneration system does not over-temperature, regenerative heat exchanger does not ice block in winter, and the dew point temperature and dry gas can be observed.
7. For control system, except drying tower, switchover of regeneration tower need manual valve, all other actions will be automatically by the device. When the work tower is adsorbing, output dry gas; when regeneration tower is adsorbing, use a control valve to control the heating temperature of heater, when the regeneration has been finished, heater will automatically stop heating, start doing cold blow, when the temperature inside of the tower blow to the set temperature, the control cabinet will automatically stop all running power system, complete regeneration; all the control parameter can be remodify on controller, flexible and easy.
8. On drying tower device has set pressure gauge, temperature meter, visual display of work pressure and regeneration temperature and other working conditions; drying tower absorption tower has set discharge port with dedicated loading, easy replacement of filling.
9. Drying tower covered with high efficient insulation coating, good effect of insulation, beautiful looking.
10. Electric heating elements are using stainless steel material, thermal conductivity of large area, heating pipe with long service life,ensured that it’s working life will not less than 3 years.
11.Cooler adopts air-cooled efficient plate heat exchanger, it is 2500~4000 M
2
/M
3
higher than surface area. Compared with the same heat transfer area of the tube-fin heat exchanger, the volume was reduced 1.3 times, weight has reduced of more than 1 time.
12. Power generation location of device is reasonable, focus on external connection, produced according DIIBT4 explosion levels.
13.Galvanized pipe through the paint treatment, outdoor installation, long-term use does not fade.
The general technical parameters that can be meet by the deep dehydration device of natural gas
1.Model Low-pressure front, ultra low pressure front, large water content, super flow, high pressure postposition etc.
2. Equipment design working pressure range
3. Maximum handing ability6000Nm
3
/h(1.0mpa)
4. Working environment temperature -30 50°C
5 .Design temperature 345°C
6. Renewable heating temperature 210~230 °C
7. Product gas ordinary pressure dew point ≤-60°C
8.Maximum water content of raw material gas≤3500PPmv
9. Equipment overall pressure drop ≤0.03MPa
10.Adsorbent Molecular sieve
11.Regenerative method Built-in electric furnace, closed loop recycling
12.Cooling-down method Air-cooled or water cooled
13. Number of drying tower 2-4 tower
14.Class of explosive-proof dIIBT4
15. Level of protection IP64
16. Power requirements 380V±7%
17.Electric power around 40% smaller than other similar manufacturers
18.Control method Dedicated control cabinet, manual switching, automatic regeneration, manual discharge
19. Equipment noise ≤70 decibel
20.Measures to Ambient temperature is below 5 prevent ice block 5 °C heating band automatically
21.Fixed mode ship-shaped skid base, without to fix, easy to install
Descriptions of features and performance of equipment
1. Equipment imported the advanced technology from Italy and the United States, novel structure, easy operation, maintenance-free after commissioning. Using the 2 to 4 tower structure for the same equipment, single-stage adsorption, can handle high water content and large flows of feed gas, big quantity of adsorption, long cycle of adsorption, low depth of dehydration, can be operate continuously, continuous output of normal atmospheric dew point lower than -60°C purity, dry gas . Eliminate duplication investment of purchase multiple equipment.
2. The unique closed-loop recycling technology, built-in electric furnace, gas through the heater, flow of gas is slow, heating time is long, with high heating efficiency, heat evenly, small heat loss, to ensure full utilization of energy and greatly reduce the electric power and renewable energy, heater power is accompanied about 60% of other manufacturers. Electric furnace with constant temperature design, the entire regeneration process control at a constant heating temperature range, avoid the damage and loss of power of the electric furnace itself by frequent starting and stopping, effectively reducing the operating costs, extend equipment’s service life.
3. Vessel shell design, manufacture, testing, acceptance according to GB150 <Steel pressure vessels>, and the State Quality and Technical Supervision issued by the <Pressure Vessel Safety Technology supervision order>. Provide a full set of the required documentation of pressure vessels.
4. Original container and furnace design, ensuring smooth gas flow, bed stability, and elimination of damage to the container due to heating or cooling; absorption tower using 16 MnR material, resistant to fatigue, to run at low pressure, the container services for a more longer time.
5. Drying tower configured a filter can effectively remove the particulate component of natural gas , outlet with a fine filter, to prevent secondary pollution caused by adsorbent off, reducing the duplication process pipeline, reducing the pressure drop of equipment, saving the user’s investment cost.
6.This device is equipped with special cabinet, can accurately control the temperature when regenerating the device process, and in accordance with set procedures for movement control regeneration system; control panel set regenerate manual and automatic mode, and manually comes priority. When the regeneration is cycling, it can start or stop the heater, cooler at any time according to actual needs. Control procedures into the work order and interlocking relationships, to avoid human errors caused the losses. Based on the cooling fan, it has set up and down line running between temperature, to ensure the regeneration system does not over-temperature, regenerative heat exchanger does not ice block in winter, and the dew point temperature and dry gas can be observed.
7. For control system, except drying tower, switchover of regeneration tower need manual valve, all other actions will be automatically by the device. When the work tower is adsorbing, output dry gas; when regeneration tower is adsorbing, use a control valve to control the heating temperature of heater, when the regeneration has been finished, heater will automatically stop heating, start doing cold blow, when the temperature inside of the tower blow to the set temperature, the control cabinet will automatically stop all running power system, complete regeneration; all the control parameter can be remodify on controller, flexible and easy.
8. On drying tower device has set pressure gauge, temperature meter, visual display of work pressure and regeneration temperature and other working conditions; drying tower absorption tower has set discharge port with dedicated loading, easy replacement of filling.
9. Drying tower covered with high efficient insulation coating, good effect of insulation, beautiful looking.
10. Electric heating elements are using stainless steel material, thermal conductivity of large area, heating pipe with long service life,ensured that it’s working life will not less than 3 years.
11.Cooler adopts air-cooled efficient plate heat exchanger, it is 2500~4000 M
2
/M
3
higher than surface area. Compared with the same heat transfer area of the tube-fin heat exchanger, the volume was reduced 1.3 times, weight has reduced of more than 1 time.
12. Power generation location of device is reasonable, focus on external connection, produced according DIIBT4 explosion levels.
13.Galvanized pipe through the paint treatment, outdoor installation, long-term use does not fade.
Natural Gas Pressure regulating station
Natural Gas Pressure regulating station
Gas metering station
SCADA system
Natural Gas Pressure Regulating Station,Gas pressure reducing & metering station
We design and manufacture the following plants:
* High Pressure City Gate and Offtake station;
* High-medium pressure Reducing & Metering Station;
* Low pressure Reducing & Metering Cabinet;
* Compressed natural gas reducing stations;
* Two-stage domestic reducing cabinet ;
* SCADA systems.
and following standard products:
* Turbine meter;
* Butterfly valve;
* Ball valve;
* Safety devices;
* Pressure regulator;
* Control valves;
* Other components.
Capacity of
completed
Natural Gas Pressure Regulating Station
Flow rate: 6000Sm3/h-160,000Sm3/h
Max Inlet pressure MPA:3.6
Min. Outlet pressure KPA:100
Application:
City gate station,long pipelines,power plant,oil field gas fuel power plant,gas turbine power plant etc.
Gas metering station
SCADA system
Natural Gas Pressure Regulating Station,Gas pressure reducing & metering station
We design and manufacture the following plants:
* High Pressure City Gate and Offtake station;
* High-medium pressure Reducing & Metering Station;
* Low pressure Reducing & Metering Cabinet;
* Compressed natural gas reducing stations;
* Two-stage domestic reducing cabinet ;
* SCADA systems.
and following standard products:
* Turbine meter;
* Butterfly valve;
* Ball valve;
* Safety devices;
* Pressure regulator;
* Control valves;
* Other components.
Capacity of
completed
Natural Gas Pressure Regulating Station
Flow rate: 6000Sm3/h-160,000Sm3/h
Max Inlet pressure MPA:3.6
Min. Outlet pressure KPA:100
Application:
City gate station,long pipelines,power plant,oil field gas fuel power plant,gas turbine power plant etc.
Natural gas generator 400KW /500KVA
Natural gas generator , with Stamford alternator
Product: Natural Gas Generaors
Power range : 200KVA to 625 KVA
Gas Engine: Chinese Top Brand Gas Engine
Alternator: Stamford
Thermal capacity:≥41860 KJ/m
3
CH
4
: ≥85% (Volume Percentage)
S:≤460 mg/ m3
H2S:≤20 mg/ m3
Gas pressure:80-100 kpa Without separator/100-500 kpa with separator
The gas should be treated without liquid. The size of impurity in the gas should be smaller than 0.005mm, and the content should be no more than 0.03g/m
3
. NoteGas volume condition: 101.3kPa20.
S
≤460 mg/ m3
Item
Specification
Thermal capacity
≥41860 KJ/m
3
CH
4
≥85% (Volume Percentage)
S
≤460 mg/ m3
H
2
S
≤20 mg/ m3
Gas pressure
80-100 kpaWithout separator/100-500 kpawith separator
Product: Natural Gas Generaors
Power range : 200KVA to 625 KVA
Gas Engine: Chinese Top Brand Gas Engine
Alternator: Stamford
Thermal capacity:≥41860 KJ/m
3
CH
4
: ≥85% (Volume Percentage)
S:≤460 mg/ m3
H2S:≤20 mg/ m3
Gas pressure:80-100 kpa Without separator/100-500 kpa with separator
The gas should be treated without liquid. The size of impurity in the gas should be smaller than 0.005mm, and the content should be no more than 0.03g/m
3
. NoteGas volume condition: 101.3kPa20.
S
≤460 mg/ m3
Item
Specification
Thermal capacity
≥41860 KJ/m
3
CH
4
≥85% (Volume Percentage)
S
≤460 mg/ m3
H
2
S
≤20 mg/ m3
Gas pressure
80-100 kpaWithout separator/100-500 kpawith separator
New GSM Gas Leak Controller alarm,S140,2 Relay outputs
GSM Gas Leak Controller alarm,S140;
4I/2O/USB Ports;
Remote control machines;
GSM SMS Remote Control;
GSM Switch
GSM Gas Leak Controller alarm,S140;
4I/2O/USB Ports;
Remote control machines;
GSM SMS Remote Control;
GSM Alarm system;GSM Switch
The GSM SMS Controller Alarm is a very simple device which can be used for authorized door access, controlling gates, switching of remote equipments, car parking systems. Actually the GSM SMS Controller can be used in places which require turning ON/OFF your system, machines, equipments remotely with a SMS text from your mobile phone and protect your assets.
Moreover, the GSM SMS Controller-Alarm with 2 digital inputs, when any one of the inputs triggered, will start the siren or switch on the light automatically. in the meanwhile, the GSM SMS Controller will send SMS Alert the to owners immediately. This is very useful if you need protect your assets with low cost solution.
Mainly Features of the GSM SMS Controller-Alarm S140:
1 relay output (240VAC@3A) can be switched ON/OFF by sending a SMS text;
1 relay output (240VAC@3A) can be switch on 4minutes if any inputs triggered;
4 Alarm logic inputs, NC or NO and EOL is optional;
3 SMS Alert numbers and 5 auto-dial numbers can accept to the alarm message;
Two-way voice communication by external microphone and speaker;
Supports armed, disarmed, inquiry status, switch on or off relay output by SMS Commands;
Password protected, prevents unauthorized user;
Can be set up and programmed from PC Programmer by USB cable;
Time stamped alarm messages;
Backup rechargeable battery inside, can work for 24hours when power off;
Can be operated from anywhere, no distance limit;
Based on GSM Network, applied to many applications.
A Professional GSM Alarms,GSM Alarm system,GSM MMS Alarm,GSM House Alarm,GSM Control Alarm, GSM SMS Alarms,Fixed Celluar Terminal,Fixed Wireless Terminal OEM ODM Manufacturer in China.
4I/2O/USB Ports;
Remote control machines;
GSM SMS Remote Control;
GSM Switch
GSM Gas Leak Controller alarm,S140;
4I/2O/USB Ports;
Remote control machines;
GSM SMS Remote Control;
GSM Alarm system;GSM Switch
The GSM SMS Controller Alarm is a very simple device which can be used for authorized door access, controlling gates, switching of remote equipments, car parking systems. Actually the GSM SMS Controller can be used in places which require turning ON/OFF your system, machines, equipments remotely with a SMS text from your mobile phone and protect your assets.
Moreover, the GSM SMS Controller-Alarm with 2 digital inputs, when any one of the inputs triggered, will start the siren or switch on the light automatically. in the meanwhile, the GSM SMS Controller will send SMS Alert the to owners immediately. This is very useful if you need protect your assets with low cost solution.
Mainly Features of the GSM SMS Controller-Alarm S140:
1 relay output (240VAC@3A) can be switched ON/OFF by sending a SMS text;
1 relay output (240VAC@3A) can be switch on 4minutes if any inputs triggered;
4 Alarm logic inputs, NC or NO and EOL is optional;
3 SMS Alert numbers and 5 auto-dial numbers can accept to the alarm message;
Two-way voice communication by external microphone and speaker;
Supports armed, disarmed, inquiry status, switch on or off relay output by SMS Commands;
Password protected, prevents unauthorized user;
Can be set up and programmed from PC Programmer by USB cable;
Time stamped alarm messages;
Backup rechargeable battery inside, can work for 24hours when power off;
Can be operated from anywhere, no distance limit;
Based on GSM Network, applied to many applications.
A Professional GSM Alarms,GSM Alarm system,GSM MMS Alarm,GSM House Alarm,GSM Control Alarm, GSM SMS Alarms,Fixed Celluar Terminal,Fixed Wireless Terminal OEM ODM Manufacturer in China.
API 5CT oil casing pipe
1. Our company has passed API certification and
2. Specialized petroleum casing pipe
3. Size: 4 1/2" -13 3/8
1. Our company is specialized in manufacturing API oil casing pipe. We have gained API 5CT and ISO9001:2000 quality certification to ensure the best quality of our products.
2. We specializing in producing petroleum casing pipe, our products are all eligible. Our oil tube has the good quality and good price. That is, you can trust us, and look forward to our first or the further cooperation.
3. The management and the employees of the company sincerely welcome domestic and foreign friends to the company for business inquiry and negotiation.
API 5CT Oil Casing Pipe
Outer Diameter
Wall Thickness
Grade
Thread
Length
in
mm
kg/m
lb/ft
4 1/2"
114.3
14.14-22.47
9.50-15.10
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
5"
127
17.11-35.86
11.50-24.10
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
5 1/2"
139.7
20.83-34.23
14.00-23.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
6 5/8"
168.28
29.76-35.72
20.00-24.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
7"
177.8
25.30-56.55
17.00-38.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
7 5/8"
193.68
35.72-63.69
24.00-42.80
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
8 5/8"
219.08
35.72-72.92
24.00-49.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
9 5/8"
244.48
48.07-86.91
32.30-58.40
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
10 3/4"
273.05
48.73-97.77
32.75-65.70
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
11 3/4"
298.45
62.50-89.29
42.00-60.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
13 3/8"
339.72
71.43-107.15
48.00-72.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
2. Specialized petroleum casing pipe
3. Size: 4 1/2" -13 3/8
1. Our company is specialized in manufacturing API oil casing pipe. We have gained API 5CT and ISO9001:2000 quality certification to ensure the best quality of our products.
2. We specializing in producing petroleum casing pipe, our products are all eligible. Our oil tube has the good quality and good price. That is, you can trust us, and look forward to our first or the further cooperation.
3. The management and the employees of the company sincerely welcome domestic and foreign friends to the company for business inquiry and negotiation.
API 5CT Oil Casing Pipe
Outer Diameter
Wall Thickness
Grade
Thread
Length
in
mm
kg/m
lb/ft
4 1/2"
114.3
14.14-22.47
9.50-15.10
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
5"
127
17.11-35.86
11.50-24.10
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
5 1/2"
139.7
20.83-34.23
14.00-23.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
6 5/8"
168.28
29.76-35.72
20.00-24.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
7"
177.8
25.30-56.55
17.00-38.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
7 5/8"
193.68
35.72-63.69
24.00-42.80
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
8 5/8"
219.08
35.72-72.92
24.00-49.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
9 5/8"
244.48
48.07-86.91
32.30-58.40
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
10 3/4"
273.05
48.73-97.77
32.75-65.70
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
11 3/4"
298.45
62.50-89.29
42.00-60.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
13 3/8"
339.72
71.43-107.15
48.00-72.00
J55/N80/P110/K55
LTC/STC/BTC
R1/R2/R3
Nitrogen Spherical Tanks
Customized model for Natural Gas Storage, for Pak industries keeping in consideration the current situation of Energy Shortage.
Specification
Wall thickness of Spherical shell plates
From 12mm to 62mm
Minimum Temperature
-50°C
Maximum single size
Width 3,650mm, length 12,580mm
Medium
Ethylene, Propylene, Oxygen, Nitrogen, Ammonia, Vinyl Chloride, natural gas, argon, Hydrogen, Liquefied Gas, LPG, LNG, Coal Gas, Water Gas, Compressed Air, Vacuum, Liquid Ammonia, Liquid Nitrogen, Refined Propylene, Butadiene, Isobutene, Propane, C3 Fraction, C4, C5, VCM, Clean Oil, Liquid Methyl Ether, Liquid Carbon Dioxide, Pulverized Coal, Light Hydrocarbon, methyl chloride, etc.
Cubage Dimension
From 50m³ to 10000m³
Note:
OEM service, provide all kinds of specifications and models of spherical tank according to customers requirements
Specification
Wall thickness of Spherical shell plates
From 12mm to 62mm
Minimum Temperature
-50°C
Maximum single size
Width 3,650mm, length 12,580mm
Medium
Ethylene, Propylene, Oxygen, Nitrogen, Ammonia, Vinyl Chloride, natural gas, argon, Hydrogen, Liquefied Gas, LPG, LNG, Coal Gas, Water Gas, Compressed Air, Vacuum, Liquid Ammonia, Liquid Nitrogen, Refined Propylene, Butadiene, Isobutene, Propane, C3 Fraction, C4, C5, VCM, Clean Oil, Liquid Methyl Ether, Liquid Carbon Dioxide, Pulverized Coal, Light Hydrocarbon, methyl chloride, etc.
Cubage Dimension
From 50m³ to 10000m³
Note:
OEM service, provide all kinds of specifications and models of spherical tank according to customers requirements