200kw Natural gas generator set adopts advanced technologies such as electronic ignitioin system,electronic governing and so o
200kw Natural gas generator set
Model of Generating Sets
200GF-T
Model of engine
W12V138DT
Rated power(KW / KVA)
200/250
Rated speed(r/min)
1500r/min
Rated voltage (V)
400
Rated current (A)
360
Rated frequency (Hz)
50
Rated power factor
0.8 Lagging
Supply method
3 phases 4 lines
Excitation method
Brushless
Starting method
Electric motor starters
Cooling method
Closed type water cooling
Bore (mm)
138
Speed modulate method
Electronic control
Net weight (kg)
3300 Kg
Overall dimension L×B×H(mm)
3058X1325X1820mm
(Reference size only)
Thursday, October 27, 2011
75kw gas generator
75kw gas generator
1. Power Saving
2. Environment Protection
3. Reasonable price and High quality.
75kw gas generator
Model of Generating Sets
75GF-T
Model of engine
H6135DT
Rated power KW
75
Rated speed r/min.
1500r/min
Rated voltage V
400
Rated current A
135
Rated frequency Hz
50
Rated power factor
0.8 Lagging
Supply method
3 phases 4 lines
Excitation method
Brushless
Starting method
Electric motor starters
Cooling method
Closed type water cooling
Bore mm
135
Speed modulate method
Electronic control
Net weight kg
2410
Overall dimension L×B×H(mm)
2750x1010x1480mm
(Reference size only)
1. Power Saving
2. Environment Protection
3. Reasonable price and High quality.
75kw gas generator
Model of Generating Sets
75GF-T
Model of engine
H6135DT
Rated power KW
75
Rated speed r/min.
1500r/min
Rated voltage V
400
Rated current A
135
Rated frequency Hz
50
Rated power factor
0.8 Lagging
Supply method
3 phases 4 lines
Excitation method
Brushless
Starting method
Electric motor starters
Cooling method
Closed type water cooling
Bore mm
135
Speed modulate method
Electronic control
Net weight kg
2410
Overall dimension L×B×H(mm)
2750x1010x1480mm
(Reference size only)
Cummins gas genset B series 30kva
Tide Power System Co., LTD. has the ability to produce Gas generators from 24kW to 220kW with the Cummins B series engine.
Technical Specification Data
Genset
Genset Model
TCM30GB
Prime Rating (kW)
24
Standby Power (kW)
26.4
Manufacturer
Tide Power System
Engine
Engine Manufacture
CUMMINS
Engine Model
4B3.9-GB
Rated Power (kW)
26
Standby Power (kW)
30
Bore× Stock (mm)
102×120
Cylinder numbers
4
Displacement (L)
3.9
Rated Speed (r/min)
1500
Intake Method
Natural
Ignition & Governing System
Omnitek US
Gas Consumption (g/kw.h)
229
Coolant Heat (kW)
25.9
Oil pan capacity: Max-Min (L)
9.5-8.5
Coolant capacity (engine only) (L)
7.2
Starter
12V/24V
Air Intake flow (L/s)
32.8
Exhaust flow (L/s)
67.5
Alternator
Alternator
Leroy-Somer,Stamford, Marathon etc
Alternator Model
LSA42.2L9
Rated Power (kW)
25.2
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
43.2
Power Factor (Cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec.
Net Weight (kg)
780
Dimension (L×W×H mm)
1650×740×1400
Technical Specification Data
Genset
Genset Model
TCM30GB
Prime Rating (kW)
24
Standby Power (kW)
26.4
Manufacturer
Tide Power System
Engine
Engine Manufacture
CUMMINS
Engine Model
4B3.9-GB
Rated Power (kW)
26
Standby Power (kW)
30
Bore× Stock (mm)
102×120
Cylinder numbers
4
Displacement (L)
3.9
Rated Speed (r/min)
1500
Intake Method
Natural
Ignition & Governing System
Omnitek US
Gas Consumption (g/kw.h)
229
Coolant Heat (kW)
25.9
Oil pan capacity: Max-Min (L)
9.5-8.5
Coolant capacity (engine only) (L)
7.2
Starter
12V/24V
Air Intake flow (L/s)
32.8
Exhaust flow (L/s)
67.5
Alternator
Alternator
Leroy-Somer,Stamford, Marathon etc
Alternator Model
LSA42.2L9
Rated Power (kW)
25.2
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
43.2
Power Factor (Cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec.
Net Weight (kg)
780
Dimension (L×W×H mm)
1650×740×1400
Cummins gas genset B series 45kva
Tide Power System Co., LTD. has the ability to produce Gas generators from 24kW to 220kW with the Cummins B series engine.
Technical Specification Data
Genset
Genset Model
TCM45GB
Prime Rating (kW)
36
Standby Power (kW)
39.6
Manufacturer
Tide Power System
Engine
Engine Manufacture
CUMMINS
Engine Model
4BT3.9-GB
Rated Power (kW)
40kW
Standby Power (kW)
44
Bore× Stock (mm)
102×120
Cylinder numbers
4
Displacement (L)
3.9
Rated Speed (r/min)
1500
Intake Method
Turbocharged
Ignition & Governing System
Omnitek US
Gas Consumption (g/kw.h)
214
Coolant Heat (kW)
25.9
Oil pan capacity: Max-Min (L)
9.5-8.5
Coolant capacity (engine only) (L)
7.2
Starter
12V/24V
Air Intake flow (L/s)
43.6
Exhaust flow (L/s)
101
Alternator
Alternator
Leroy-Somer,Stamford, Marathon etc
Alternator Model
LSA43.2S25
Rated Power (kW)
36
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
64.8
Power Factor (Cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec.
Net Weight (kg)
820
Dimension (L×W×H mm)
1700×740×1400
Technical Specification Data
Genset
Genset Model
TCM45GB
Prime Rating (kW)
36
Standby Power (kW)
39.6
Manufacturer
Tide Power System
Engine
Engine Manufacture
CUMMINS
Engine Model
4BT3.9-GB
Rated Power (kW)
40kW
Standby Power (kW)
44
Bore× Stock (mm)
102×120
Cylinder numbers
4
Displacement (L)
3.9
Rated Speed (r/min)
1500
Intake Method
Turbocharged
Ignition & Governing System
Omnitek US
Gas Consumption (g/kw.h)
214
Coolant Heat (kW)
25.9
Oil pan capacity: Max-Min (L)
9.5-8.5
Coolant capacity (engine only) (L)
7.2
Starter
12V/24V
Air Intake flow (L/s)
43.6
Exhaust flow (L/s)
101
Alternator
Alternator
Leroy-Somer,Stamford, Marathon etc
Alternator Model
LSA43.2S25
Rated Power (kW)
36
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
64.8
Power Factor (Cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec.
Net Weight (kg)
820
Dimension (L×W×H mm)
1700×740×1400
Cummins gas genset B series 63kva
Tide Power System Co., LTD. has the ability to produce Gas generators from 24kW to 220kW with the Cummins B series engine.
Technical Specification Data
Genset
Genset Model
TCM63GB
Prime Rating (kW)
50
Standby Power (kW)
55
Manufacturer
Tide Power System
Engine
Engine Manufacture
CUMMINS
Engine Model
4BTA3.9-GB
Rated Power (kW)
55
Standby Power (kW)
61
Bore× Stock (mm)
102×120
Cylinder numbers
4
Displacement (L)
3.9
Rated Speed (r/min)
1500
Intake Method
Turbocharged, air-water inter-cooled
Ignition & Governing System
Omnitek US
Gas Consumption (g/kw.h)
214
Coolant Heat (kW)
25.9
Oil pan capacity: Max-Min
9.5-8.5L
Coolant capacity (engine only) (L)
7.2
Starter
12V/24V
Air Intake flow (L/s)
48
Exhaust flow (L/s)
130
Alternator
Alternator
Leroy-Somer,Stamford, Marathon etc
Alternator Model
LSA43.2L65
Rated Power (kW)
56
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
91
Power Factor (Cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec.
Net Weight (kg)
900
Dimension (L×W×H mm)
1750×740×1400
Technical Specification Data
Genset
Genset Model
TCM63GB
Prime Rating (kW)
50
Standby Power (kW)
55
Manufacturer
Tide Power System
Engine
Engine Manufacture
CUMMINS
Engine Model
4BTA3.9-GB
Rated Power (kW)
55
Standby Power (kW)
61
Bore× Stock (mm)
102×120
Cylinder numbers
4
Displacement (L)
3.9
Rated Speed (r/min)
1500
Intake Method
Turbocharged, air-water inter-cooled
Ignition & Governing System
Omnitek US
Gas Consumption (g/kw.h)
214
Coolant Heat (kW)
25.9
Oil pan capacity: Max-Min
9.5-8.5L
Coolant capacity (engine only) (L)
7.2
Starter
12V/24V
Air Intake flow (L/s)
48
Exhaust flow (L/s)
130
Alternator
Alternator
Leroy-Somer,Stamford, Marathon etc
Alternator Model
LSA43.2L65
Rated Power (kW)
56
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
91
Power Factor (Cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec.
Net Weight (kg)
900
Dimension (L×W×H mm)
1750×740×1400
DAEWOO Series Gas Genset
Tide Power System Co., LTD. gas genset has so many features such as widely adoption of gas, high average effective pressure.
Output Power 50Hz/400V 60Hz/440V
Prime Power
kVA
315
360
kW
252
288
Standby Power
kVA
347
396
kW
278
317
Dimension
mm
3000X1390X1820
Weight
kg
2580
Engine Data
Manufacturer
DAEWOO
Engine Model
GV180TIR
No. of Cylinders and Configuration
10 V Type
Displacement
L
18.273
Bore × Stroke
mm
128×142
Compression Ratio
10.5:1
Aspiration
Turbocharged and Intercooled (Water to Air)
Governor Type
Electronic
Cooling System
Water
Coolant Capacity
L
238
Lubrication Oil Capacity
L
35
Electrical System
VDC
24
Speed/Frequency
rpm/Hz
1500/50
1800/60
Engine Gross Power
kW
319
375
Fuel Consumption Nm
3
/h
110% loading
80.5
99.5
100% loading
74.7
90.8
75% loading
57.4
71.7
50% loading
41.5
50.6
Exhaust Outlet Temp.
520
530
Exhaust Gas Flow
m
3
/min
30
37.8
Combustion Air Flow
m
3
/min
38.8
47.9
Cooling Air Flow
m
3
/min
23.9
29.4
Alternator
Manufacturer
Leroy-Somer
Model
LSA46.2VL12
Phase and Wire
3 Phase 4Wire
Power Factor
0.8
No. of Poles
4
No. of Leads
12
Insulation Class
H
Protection Class
IP23
Frequency
Hz
50Hz
60Hz
Voltage
400V/230V
440V/254V
Rated Power
kW
252
298
Output Power 50Hz/400V 60Hz/440V
Prime Power
kVA
315
360
kW
252
288
Standby Power
kVA
347
396
kW
278
317
Dimension
mm
3000X1390X1820
Weight
kg
2580
Engine Data
Manufacturer
DAEWOO
Engine Model
GV180TIR
No. of Cylinders and Configuration
10 V Type
Displacement
L
18.273
Bore × Stroke
mm
128×142
Compression Ratio
10.5:1
Aspiration
Turbocharged and Intercooled (Water to Air)
Governor Type
Electronic
Cooling System
Water
Coolant Capacity
L
238
Lubrication Oil Capacity
L
35
Electrical System
VDC
24
Speed/Frequency
rpm/Hz
1500/50
1800/60
Engine Gross Power
kW
319
375
Fuel Consumption Nm
3
/h
110% loading
80.5
99.5
100% loading
74.7
90.8
75% loading
57.4
71.7
50% loading
41.5
50.6
Exhaust Outlet Temp.
520
530
Exhaust Gas Flow
m
3
/min
30
37.8
Combustion Air Flow
m
3
/min
38.8
47.9
Cooling Air Flow
m
3
/min
23.9
29.4
Alternator
Manufacturer
Leroy-Somer
Model
LSA46.2VL12
Phase and Wire
3 Phase 4Wire
Power Factor
0.8
No. of Poles
4
No. of Leads
12
Insulation Class
H
Protection Class
IP23
Frequency
Hz
50Hz
60Hz
Voltage
400V/230V
440V/254V
Rated Power
kW
252
298
DEUTZ gas genset 30kva
Tide Power System Co., LTD. has so many features such as widely adoption of gas, high average effective pressure, low heat load
Technical Specification Data
Genset
Genset Model
TDE30G
Prime Rating (kW)
24
Standby Power (kW)
26.4
Heat Consumption (MJ/kWh)
12
Engine
Engine Manufacture
DEUTZ
Engine Model
TBD226B-3DG
Bore× Stock (mm)
105×120
Cylinder numbers
3
Rated Speed (r/min)
1500
12-hour Power (kW)
37
Intaking Method
Turbocharged
Reference Gas Consumption (m
3
/h)
10
Reference Air Consumption (m
3
/h)
125
Coolant Heat (kW)
27.2
Coolant Flux (kg/s)
1.1
Fan-air Flux (m
3
/h)
1.9
Exhaust Flux (m
3
/h)
401
Starting Method
Electrical Starting
Alternator
Alternator
Leroy-Somer, Siemens, Marathon etc
Alternator Model
UCI224C
Rated Power (kW)
34
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
61
Power Factor (cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec
Net Weight (kg)
760
Dimension (L×W×H mm)
1900×788×1200
Technical Specification Data
Genset
Genset Model
TDE30G
Prime Rating (kW)
24
Standby Power (kW)
26.4
Heat Consumption (MJ/kWh)
12
Engine
Engine Manufacture
DEUTZ
Engine Model
TBD226B-3DG
Bore× Stock (mm)
105×120
Cylinder numbers
3
Rated Speed (r/min)
1500
12-hour Power (kW)
37
Intaking Method
Turbocharged
Reference Gas Consumption (m
3
/h)
10
Reference Air Consumption (m
3
/h)
125
Coolant Heat (kW)
27.2
Coolant Flux (kg/s)
1.1
Fan-air Flux (m
3
/h)
1.9
Exhaust Flux (m
3
/h)
401
Starting Method
Electrical Starting
Alternator
Alternator
Leroy-Somer, Siemens, Marathon etc
Alternator Model
UCI224C
Rated Power (kW)
34
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
61
Power Factor (cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec
Net Weight (kg)
760
Dimension (L×W×H mm)
1900×788×1200
DOT standard CNG Cylinder
DOT standart CNG cylinder .work pressure 3600PSI. NGV cylinder valve .
DOT standart CNG cylinder work pressure is higher than ISO11439:2000 in according ANSI complllent request. The CNG cylinder must with DOT-3AA stamping on body .
CNG cylinder under DOT standart have following request
Work pressure 3600PSI
Test Pressure 4200PSI
SYP offer CNG cylinder /NGV cylinder with DOT-3AA stamping . the seriese cover Type 1 steel cylinder, Type 2 galss fiber wrapped cng cylinder .
we offer 325 serise 60L, 80L,90L,100L type 2 CNG cylinder with DOT approve ,50,60,70,80,90,100,120,145L type 1 CNG steel cylinder
SYP also offer customer the EPA request mutivevalve for DOT cylinder .please contact with us for more information
DOT standart CNG cylinder work pressure is higher than ISO11439:2000 in according ANSI complllent request. The CNG cylinder must with DOT-3AA stamping on body .
CNG cylinder under DOT standart have following request
Work pressure 3600PSI
Test Pressure 4200PSI
SYP offer CNG cylinder /NGV cylinder with DOT-3AA stamping . the seriese cover Type 1 steel cylinder, Type 2 galss fiber wrapped cng cylinder .
we offer 325 serise 60L, 80L,90L,100L type 2 CNG cylinder with DOT approve ,50,60,70,80,90,100,120,145L type 1 CNG steel cylinder
SYP also offer customer the EPA request mutivevalve for DOT cylinder .please contact with us for more information
Deep Dehydration Device Of Natural Gas
Is especially used for deep dehydration of natural gas in CNG gas filling station
The general technical parameters that can be meet by the deep dehydration device of natural gas
1.Model Low-pressure front, ultra low pressure front, large water content, super flow, high pressure postposition etc.
2. Equipment design working pressure range
3. Maximum handing ability6000Nm
3
/h(1.0mpa)
4. Working environment temperature -30 50°C
5 .Design temperature 345°C
6. Renewable heating temperature 210~230 °C
7. Product gas ordinary pressure dew point ≤-60°C
8.Maximum water content of raw material gas≤3500PPmv
9. Equipment overall pressure drop ≤0.03MPa
10.Adsorbent Molecular sieve
11.Regenerative method Built-in electric furnace, closed loop recycling
12.Cooling-down method Air-cooled or water cooled
13. Number of drying tower 2-4 tower
14.Class of explosive-proof dIIBT4
15. Level of protection IP64
16. Power requirements 380V±7%
17.Electric power around 40% smaller than other similar manufacturers
18.Control method Dedicated control cabinet, manual switching, automatic regeneration, manual discharge
19. Equipment noise ≤70 decibel
20.Measures to Ambient temperature is below 5 prevent ice block 5 °C heating band automatically
21.Fixed mode ship-shaped skid base, without to fix, easy to install
Descriptions of features and performance of equipment
1. Equipment imported the advanced technology from Italy and the United States, novel structure, easy operation, maintenance-free after commissioning. Using the 2 to 4 tower structure for the same equipment, single-stage adsorption, can handle high water content and large flows of feed gas, big quantity of adsorption, long cycle of adsorption, low depth of dehydration, can be operate continuously, continuous output of normal atmospheric dew point lower than -60°C purity, dry gas . Eliminate duplication investment of purchase multiple equipment.
2. The unique closed-loop recycling technology, built-in electric furnace, gas through the heater, flow of gas is slow, heating time is long, with high heating efficiency, heat evenly, small heat loss, to ensure full utilization of energy and greatly reduce the electric power and renewable energy, heater power is accompanied about 60% of other manufacturers. Electric furnace with constant temperature design, the entire regeneration process control at a constant heating temperature range, avoid the damage and loss of power of the electric furnace itself by frequent starting and stopping, effectively reducing the operating costs, extend equipment’s service life.
3. Vessel shell design, manufacture, testing, acceptance according to GB150 <Steel pressure vessels>, and the State Quality and Technical Supervision issued by the <Pressure Vessel Safety Technology supervision order>. Provide a full set of the required documentation of pressure vessels.
4. Original container and furnace design, ensuring smooth gas flow, bed stability, and elimination of damage to the container due to heating or cooling; absorption tower using 16 MnR material, resistant to fatigue, to run at low pressure, the container services for a more longer time.
5. Drying tower configured a filter can effectively remove the particulate component of natural gas , outlet with a fine filter, to prevent secondary pollution caused by adsorbent off, reducing the duplication process pipeline, reducing the pressure drop of equipment, saving the user’s investment cost.
6.This device is equipped with special cabinet, can accurately control the temperature when regenerating the device process, and in accordance with set procedures for movement control regeneration system; control panel set regenerate manual and automatic mode, and manually comes priority. When the regeneration is cycling, it can start or stop the heater, cooler at any time according to actual needs. Control procedures into the work order and interlocking relationships, to avoid human errors caused the losses. Based on the cooling fan, it has set up and down line running between temperature, to ensure the regeneration system does not over-temperature, regenerative heat exchanger does not ice block in winter, and the dew point temperature and dry gas can be observed.
7. For control system, except drying tower, switchover of regeneration tower need manual valve, all other actions will be automatically by the device. When the work tower is adsorbing, output dry gas; when regeneration tower is adsorbing, use a control valve to control the heating temperature of heater, when the regeneration has been finished, heater will automatically stop heating, start doing cold blow, when the temperature inside of the tower blow to the set temperature, the control cabinet will automatically stop all running power system, complete regeneration; all the control parameter can be remodify on controller, flexible and easy.
8. On drying tower device has set pressure gauge, temperature meter, visual display of work pressure and regeneration temperature and other working conditions; drying tower absorption tower has set discharge port with dedicated loading, easy replacement of filling.
9. Drying tower covered with high efficient insulation coating, good effect of insulation, beautiful looking.
10. Electric heating elements are using stainless steel material, thermal conductivity of large area, heating pipe with long service life,ensured that it’s working life will not less than 3 years.
11.Cooler adopts air-cooled efficient plate heat exchanger, it is 2500~4000 M
2
/M
3
higher than surface area. Compared with the same heat transfer area of the tube-fin heat exchanger, the volume was reduced 1.3 times, weight has reduced of more than 1 time.
12. Power generation location of device is reasonable, focus on external connection, produced according DIIBT4 explosion levels.
13.Galvanized pipe through the paint treatment, outdoor installation, long-term use does not fade.
The general technical parameters that can be meet by the deep dehydration device of natural gas
1.Model Low-pressure front, ultra low pressure front, large water content, super flow, high pressure postposition etc.
2. Equipment design working pressure range
3. Maximum handing ability6000Nm
3
/h(1.0mpa)
4. Working environment temperature -30 50°C
5 .Design temperature 345°C
6. Renewable heating temperature 210~230 °C
7. Product gas ordinary pressure dew point ≤-60°C
8.Maximum water content of raw material gas≤3500PPmv
9. Equipment overall pressure drop ≤0.03MPa
10.Adsorbent Molecular sieve
11.Regenerative method Built-in electric furnace, closed loop recycling
12.Cooling-down method Air-cooled or water cooled
13. Number of drying tower 2-4 tower
14.Class of explosive-proof dIIBT4
15. Level of protection IP64
16. Power requirements 380V±7%
17.Electric power around 40% smaller than other similar manufacturers
18.Control method Dedicated control cabinet, manual switching, automatic regeneration, manual discharge
19. Equipment noise ≤70 decibel
20.Measures to Ambient temperature is below 5 prevent ice block 5 °C heating band automatically
21.Fixed mode ship-shaped skid base, without to fix, easy to install
Descriptions of features and performance of equipment
1. Equipment imported the advanced technology from Italy and the United States, novel structure, easy operation, maintenance-free after commissioning. Using the 2 to 4 tower structure for the same equipment, single-stage adsorption, can handle high water content and large flows of feed gas, big quantity of adsorption, long cycle of adsorption, low depth of dehydration, can be operate continuously, continuous output of normal atmospheric dew point lower than -60°C purity, dry gas . Eliminate duplication investment of purchase multiple equipment.
2. The unique closed-loop recycling technology, built-in electric furnace, gas through the heater, flow of gas is slow, heating time is long, with high heating efficiency, heat evenly, small heat loss, to ensure full utilization of energy and greatly reduce the electric power and renewable energy, heater power is accompanied about 60% of other manufacturers. Electric furnace with constant temperature design, the entire regeneration process control at a constant heating temperature range, avoid the damage and loss of power of the electric furnace itself by frequent starting and stopping, effectively reducing the operating costs, extend equipment’s service life.
3. Vessel shell design, manufacture, testing, acceptance according to GB150 <Steel pressure vessels>, and the State Quality and Technical Supervision issued by the <Pressure Vessel Safety Technology supervision order>. Provide a full set of the required documentation of pressure vessels.
4. Original container and furnace design, ensuring smooth gas flow, bed stability, and elimination of damage to the container due to heating or cooling; absorption tower using 16 MnR material, resistant to fatigue, to run at low pressure, the container services for a more longer time.
5. Drying tower configured a filter can effectively remove the particulate component of natural gas , outlet with a fine filter, to prevent secondary pollution caused by adsorbent off, reducing the duplication process pipeline, reducing the pressure drop of equipment, saving the user’s investment cost.
6.This device is equipped with special cabinet, can accurately control the temperature when regenerating the device process, and in accordance with set procedures for movement control regeneration system; control panel set regenerate manual and automatic mode, and manually comes priority. When the regeneration is cycling, it can start or stop the heater, cooler at any time according to actual needs. Control procedures into the work order and interlocking relationships, to avoid human errors caused the losses. Based on the cooling fan, it has set up and down line running between temperature, to ensure the regeneration system does not over-temperature, regenerative heat exchanger does not ice block in winter, and the dew point temperature and dry gas can be observed.
7. For control system, except drying tower, switchover of regeneration tower need manual valve, all other actions will be automatically by the device. When the work tower is adsorbing, output dry gas; when regeneration tower is adsorbing, use a control valve to control the heating temperature of heater, when the regeneration has been finished, heater will automatically stop heating, start doing cold blow, when the temperature inside of the tower blow to the set temperature, the control cabinet will automatically stop all running power system, complete regeneration; all the control parameter can be remodify on controller, flexible and easy.
8. On drying tower device has set pressure gauge, temperature meter, visual display of work pressure and regeneration temperature and other working conditions; drying tower absorption tower has set discharge port with dedicated loading, easy replacement of filling.
9. Drying tower covered with high efficient insulation coating, good effect of insulation, beautiful looking.
10. Electric heating elements are using stainless steel material, thermal conductivity of large area, heating pipe with long service life,ensured that it’s working life will not less than 3 years.
11.Cooler adopts air-cooled efficient plate heat exchanger, it is 2500~4000 M
2
/M
3
higher than surface area. Compared with the same heat transfer area of the tube-fin heat exchanger, the volume was reduced 1.3 times, weight has reduced of more than 1 time.
12. Power generation location of device is reasonable, focus on external connection, produced according DIIBT4 explosion levels.
13.Galvanized pipe through the paint treatment, outdoor installation, long-term use does not fade.
Wednesday, October 26, 2011
Deutz gas genset 45kva
Tide Power System Co., LTD. has so many features such as widely adoption of gas, high average effective pressure, low heat load
Technical Specification Data
Genset
Genset Model
TDE45G
Prime Rating (kW)
36
Standby Power (kW)
40
Heat Consumption (MJ/kWh)
12
Engine
Engine Manufacture
DEUTZ
Engine Model
TBD226B-4DG
Bore× Stock (mm)
105×120
Cylinder numbers
4
Rated Speed (r/min)
1500
12-hour Power (kW)
48
Intaking Method
Turbocharged
Reference Gas Consumption (m
3
/h)
14
Reference Air Consumption (m
3
/h)
168
Coolant Heat (kW)
36.6
Coolant Flux (kg/s)
1.4
Fan-air Flux (m
3
/h)
2.5
Exhaust Flux (m
3
/h)
538
Starting Method
Electrical Starting
Alternator
Alternator
Leroy-Somer, Siemens, Marathon etc
Alternator Model
UCI224E
Rated Power (kW)
48
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
87
Power Factor (cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec
Net Weight (kg)
860
Dimension (L×W×H mm)
1950×788×1400
Technical Specification Data
Genset
Genset Model
TDE45G
Prime Rating (kW)
36
Standby Power (kW)
40
Heat Consumption (MJ/kWh)
12
Engine
Engine Manufacture
DEUTZ
Engine Model
TBD226B-4DG
Bore× Stock (mm)
105×120
Cylinder numbers
4
Rated Speed (r/min)
1500
12-hour Power (kW)
48
Intaking Method
Turbocharged
Reference Gas Consumption (m
3
/h)
14
Reference Air Consumption (m
3
/h)
168
Coolant Heat (kW)
36.6
Coolant Flux (kg/s)
1.4
Fan-air Flux (m
3
/h)
2.5
Exhaust Flux (m
3
/h)
538
Starting Method
Electrical Starting
Alternator
Alternator
Leroy-Somer, Siemens, Marathon etc
Alternator Model
UCI224E
Rated Power (kW)
48
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
87
Power Factor (cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec
Net Weight (kg)
860
Dimension (L×W×H mm)
1950×788×1400
Deutz gas genset 90KVA
Tide Power System Co., LTD. has so many features such as widely adoption of gas, high average effective pressure, low heat load
Technical Specification Data
Genset
Genset Model
TDE90G
Prime Rating (kW)
72
Standby Power (kW)
79
Heat Consumption (MJ/kWh)
12
Engine
Engine Manufacture
DEUTZ
Engine Model
TBD226B-6DG
Bore× Stock (mm)
105×120
Cylinder numbers
6
Rated Speed (r/min)
1500
12-hour Power (kW)
100
Intaking Method
Turbocharged Intercooled
Reference Gas Consumption (m
3
/h)
29
Reference Air Consumption (m
3
/h)
356
Coolant Heat (kW)
77.4
Coolant Flux (kg/s)
3.1
Fan-air Flux (m
3
/h)
5.3
Exhaust Flux (m
3
/h)
1139
Starting Method
Electrical Starting
Alternator
Alternator
Leroy-Somer, Siemens, Marathon etc
Alternator Model
UCI274D
Rated Power (kW)
96
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
173
Power Factor (cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec
Net Weight (kg)
1290
Dimension (L×W×H mm)
2400×788×1450
Technical Specification Data
Genset
Genset Model
TDE90G
Prime Rating (kW)
72
Standby Power (kW)
79
Heat Consumption (MJ/kWh)
12
Engine
Engine Manufacture
DEUTZ
Engine Model
TBD226B-6DG
Bore× Stock (mm)
105×120
Cylinder numbers
6
Rated Speed (r/min)
1500
12-hour Power (kW)
100
Intaking Method
Turbocharged Intercooled
Reference Gas Consumption (m
3
/h)
29
Reference Air Consumption (m
3
/h)
356
Coolant Heat (kW)
77.4
Coolant Flux (kg/s)
3.1
Fan-air Flux (m
3
/h)
5.3
Exhaust Flux (m
3
/h)
1139
Starting Method
Electrical Starting
Alternator
Alternator
Leroy-Somer, Siemens, Marathon etc
Alternator Model
UCI274D
Rated Power (kW)
96
Frequency (HZ)
50
Rated Voltage (V)
400/230
Rated Current (A)
173
Power Factor (cosφ)
0.8
Excitation Method
Brushless
V-regulator Method
Automatic
Phase/Connection
3 Phase 4 Wire, Y-connection
Spec
Net Weight (kg)
1290
Dimension (L×W×H mm)
2400×788×1450
Dispenser
CNG dispenser standard refueling station
cost saving and environment friendly
CNG Dispenser Standard Refueling Station
Model:
JQDS-30A(3MBW)
Measuring accuracies
±0.5%
Range of flow
2~30Nm3/min /Gun
Rated working pressure
20Mpa
Maximum working pressure
25Mpa
Design pressure
27.5Mpa
Refueling pressure
20Mpa
Volume for single charging
9999.99 m
3
Volume for accumulation
99999999.99 m
3
Intensity of pressure resistance
37.5Mpa
Work power source
220V±20% 50Hz±1Hz
Packing dimension:
1200×740×2100
Measuring unit
It can be set according to client’s requirements.
CNG Dispenser Standard Refueling Station
Model:
JQDS-30A(3MBW)
Measuring accuracies
±0.5%
Range of flow
2~30Nm3/min /Gun
Rated working pressure
20Mpa
Maximum working pressure
25Mpa
Design pressure
27.5Mpa
Refueling pressure
20Mpa
Volume for single charging
9999.99 m
3
Volume for accumulation
99999999.99 m
3
Intensity of pressure resistance
37.5Mpa
Explosion-proof rank
Exibdme Two AT4
Work power source
220V±20% 50Hz±1Hz
Power
Less than 200W
Packing dimension:
1200×740×2100
Measuring unit
It can be set according to client’s requirements.
cost saving and environment friendly
CNG Dispenser Standard Refueling Station
Model:
JQDS-30A(3MBW)
Measuring accuracies
±0.5%
Range of flow
2~30Nm3/min /Gun
Rated working pressure
20Mpa
Maximum working pressure
25Mpa
Design pressure
27.5Mpa
Refueling pressure
20Mpa
Volume for single charging
9999.99 m
3
Volume for accumulation
99999999.99 m
3
Intensity of pressure resistance
37.5Mpa
Work power source
220V±20% 50Hz±1Hz
Packing dimension:
1200×740×2100
Measuring unit
It can be set according to client’s requirements.
CNG Dispenser Standard Refueling Station
Model:
JQDS-30A(3MBW)
Measuring accuracies
±0.5%
Range of flow
2~30Nm3/min /Gun
Rated working pressure
20Mpa
Maximum working pressure
25Mpa
Design pressure
27.5Mpa
Refueling pressure
20Mpa
Volume for single charging
9999.99 m
3
Volume for accumulation
99999999.99 m
3
Intensity of pressure resistance
37.5Mpa
Explosion-proof rank
Exibdme Two AT4
Work power source
220V±20% 50Hz±1Hz
Power
Less than 200W
Packing dimension:
1200×740×2100
Measuring unit
It can be set according to client’s requirements.
75kw genset
genset advantages
1. Power Saving
2. Environment Protection
3. Reasonable price and High quality.
75kw
genset
for natural gas
Model of Generating Sets
75GF-T
Model of engine
H6135DT
Rated power KW
75
Rated speed r/min.
1500r/min
Rated voltage V
400
Rated current A
135
Rated frequency Hz
50
Rated power factor
0.8 Lagging
Supply method
3 phases 4 lines
Excitation method
Brushless
Starting method
Electric motor starters
Cooling method
Closed type water cooling
Bore mm
135
Speed modulate method
Electronic control
Net weight kg
2410
Overall dimension L×B×H(mm)
2750x1010x1480mm
(Reference size only)
1. Power Saving
2. Environment Protection
3. Reasonable price and High quality.
75kw
genset
for natural gas
Model of Generating Sets
75GF-T
Model of engine
H6135DT
Rated power KW
75
Rated speed r/min.
1500r/min
Rated voltage V
400
Rated current A
135
Rated frequency Hz
50
Rated power factor
0.8 Lagging
Supply method
3 phases 4 lines
Excitation method
Brushless
Starting method
Electric motor starters
Cooling method
Closed type water cooling
Bore mm
135
Speed modulate method
Electronic control
Net weight kg
2410
Overall dimension L×B×H(mm)
2750x1010x1480mm
(Reference size only)
Extrusive PVDF rod
So far, our company has successfully developed d3-d300mm of PVDF extrusive rod ,widely used in various fields .
tem
thinckness
width
length
Application
Stamped sheet
1-50mm
100-1000mm
100-2000mm
insulating parts,anticorrosivelining
seal
Extrusion sheet
0.05-0.5
≤500
≥10000
PVDF sheet ,Board conforms to the respective standards
Item
Dia
Length
Application
Stamping rod
5-20
200
In-process antisepsis,steel ,insulating component
25-100
100-150
Extrusion tube
3-150
≥4000
Pipeline for corrosive liquid and gas, protecting tube for Electric wire
PVDF rod and tube conforms to the respective standards .
tem
thinckness
width
length
Application
Stamped sheet
1-50mm
100-1000mm
100-2000mm
insulating parts,anticorrosivelining
seal
Extrusion sheet
0.05-0.5
≤500
≥10000
PVDF sheet ,Board conforms to the respective standards
Item
Dia
Length
Application
Stamping rod
5-20
200
In-process antisepsis,steel ,insulating component
25-100
100-150
Extrusion tube
3-150
≥4000
Pipeline for corrosive liquid and gas, protecting tube for Electric wire
PVDF rod and tube conforms to the respective standards .
FEP wire
FEP wire
resistance to high temperature.
high chemical stability
the insulating property is good.
Fluorinated ethylene propylene(FEP
,
F46) products
FEP is a modified category of PTFE. It remains basically the properties of PTFE, like excellent high- low-temperature resistance, chemical stability, dielectricity, high non-adhesiveness and mechanical strength. Compare to PTFE, it has better elasticity and transparency and is only 50 lower than PTFE by limit of high temperature resistance.
Main technical indicators of FEP
Indicator
Unit
Indicator figure
Rod, sheet
Tube, membrane
density
g/cm
3
2.14-2.17
Tensile strength
Mpa
20
14
Ultimate elongation
%
200
175
Temperature range
°C
- 196-200
Dielectricity strength
Kv/mm
15
Specification and application of FEP products
FEP sheet, membrane unit:mm
Type
Thickness
width
length
Application
Molded sheet
1—50
100—400
100—400
Anti-corrosion, seal, antifriction, insulation parts
Blow molded membrane
0.03—0.2
≤600
≥10000
Anti-corrosion, anti-adhesiveness, photic parts, capacitor insulation
Extruded sheet
0.05—0.5
≤500
≥10000
FEP sheet, membrane is compatible to corresponding standard.
resistance to high temperature.
high chemical stability
the insulating property is good.
Fluorinated ethylene propylene(FEP
,
F46) products
FEP is a modified category of PTFE. It remains basically the properties of PTFE, like excellent high- low-temperature resistance, chemical stability, dielectricity, high non-adhesiveness and mechanical strength. Compare to PTFE, it has better elasticity and transparency and is only 50 lower than PTFE by limit of high temperature resistance.
Main technical indicators of FEP
Indicator
Unit
Indicator figure
Rod, sheet
Tube, membrane
density
g/cm
3
2.14-2.17
Tensile strength
Mpa
20
14
Ultimate elongation
%
200
175
Temperature range
°C
- 196-200
Dielectricity strength
Kv/mm
15
Specification and application of FEP products
FEP sheet, membrane unit:mm
Type
Thickness
width
length
Application
Molded sheet
1—50
100—400
100—400
Anti-corrosion, seal, antifriction, insulation parts
Blow molded membrane
0.03—0.2
≤600
≥10000
Anti-corrosion, anti-adhesiveness, photic parts, capacitor insulation
Extruded sheet
0.05—0.5
≤500
≥10000
FEP sheet, membrane is compatible to corresponding standard.
Fleet cng fuleing compressor SYP-C-12-P36
CNG compressor for fleet use , 220V ,1 phase power, 17A , work presure 3600 PSI . complet cng fuleing sytem with UL/CSA approve
SYP clean energy cng home fueling station with the new update in according to CSA/UL standard. With 1000 hours durability life testing . SYP give customer the 4000 Hours warrnaty for long term running running process for our customer
All SYP cng home fueling station we offer to customer is complet set : . including :
CNG compresosr unit, safe manage control panel. high presusre fueling hose and autoblow down system
All the design and life test is base on
CSA/UL standard . NFPA 52 /70/UL519 standard
All the insall and warranty process :
will be handle by our authorized distributor
Average discharge volume is from :
2 GGGE to 3.4GGE /Hours
Averagne power consume
4.4Kw
Inlet presure base on
5 PSI to 45 PSI
Work presusre
3600 PSI
Auto blow down system including
: 3600 PSI auto blow down valve
Fuel Nozzle :
NGV-2 approve by ANGI , Work pressure 3600 PSI
Control Systme :
Automaitc working sytem with Safe management PLC unit
Easy operate system :
Touch screen for easy operate
Work Power
220V 1 phase for redidentail garage install / 17 A
We product the best cng home fueling statoin in according to legal way with CSA/UL approve . Please contact with us or our distributor for the new design order . please ensure the distribuotr is with SYP authorized
CNG home fueling station deal with hazard gas during high pressure. Please ensure the install process is meet UL519/NFPA52 for residential garage or Outdoor in according to Federal law.
SYP distributor would like support you install the station with legal way. Please reference our authorized agency from our website
www.sypcleanenergy.com
SYP clean energy cng home fueling station with the new update in according to CSA/UL standard. With 1000 hours durability life testing . SYP give customer the 4000 Hours warrnaty for long term running running process for our customer
All SYP cng home fueling station we offer to customer is complet set : . including :
CNG compresosr unit, safe manage control panel. high presusre fueling hose and autoblow down system
All the design and life test is base on
CSA/UL standard . NFPA 52 /70/UL519 standard
All the insall and warranty process :
will be handle by our authorized distributor
Average discharge volume is from :
2 GGGE to 3.4GGE /Hours
Averagne power consume
4.4Kw
Inlet presure base on
5 PSI to 45 PSI
Work presusre
3600 PSI
Auto blow down system including
: 3600 PSI auto blow down valve
Fuel Nozzle :
NGV-2 approve by ANGI , Work pressure 3600 PSI
Control Systme :
Automaitc working sytem with Safe management PLC unit
Easy operate system :
Touch screen for easy operate
Work Power
220V 1 phase for redidentail garage install / 17 A
We product the best cng home fueling statoin in according to legal way with CSA/UL approve . Please contact with us or our distributor for the new design order . please ensure the distribuotr is with SYP authorized
CNG home fueling station deal with hazard gas during high pressure. Please ensure the install process is meet UL519/NFPA52 for residential garage or Outdoor in according to Federal law.
SYP distributor would like support you install the station with legal way. Please reference our authorized agency from our website
www.sypcleanenergy.com
Gas Dehydration Device
Is especially used for deep dehydration of natural gas in CNG gas filling station
The general technical parameters that can be meet by the deep dehydration device of natural gas
1.Model Low-pressure front, ultra low pressure front, large water content, super flow, high pressure postposition etc.
2. Equipment design working pressure range
3. Maximum handing ability6000Nm
3
/h(1.0mpa)
4. Working environment temperature -30 50°C
5 .Design temperature 345°C
6. Renewable heating temperature 210~230 °C
7. Product gas ordinary pressure dew point ≤-60°C
8.Maximum water content of raw material gas≤3500PPmv
9. Equipment overall pressure drop ≤0.03MPa
10.Adsorbent Molecular sieve
11.Regenerative method Built-in electric furnace, closed loop recycling
12.Cooling-down method Air-cooled or water cooled
13. Number of drying tower 2-4 tower
14.Class of explosive-proof dIIBT4
15. Level of protection IP64
16. Power requirements 380V±7%
17.Electric power around 40% smaller than other similar manufacturers
18.Control method Dedicated control cabinet, manual switching, automatic regeneration, manual discharge
19. Equipment noise ≤70 decibel
20.Measures to Ambient temperature is below 5 prevent ice block 5 °C heating band automatically
21.Fixed mode ship-shaped skid base, without to fix, easy to install
Descriptions of features and performance of equipment
1. Equipment imported the advanced technology from Italy and the United States, novel structure, easy operation, maintenance-free after commissioning. Using the 2 to 4 tower structure for the same equipment, single-stage adsorption, can handle high water content and large flows of feed gas, big quantity of adsorption, long cycle of adsorption, low depth of dehydration, can be operate continuously, continuous output of normal atmospheric dew point lower than -60°C purity, dry gas . Eliminate duplication investment of purchase multiple equipment.
2. The unique closed-loop recycling technology, built-in electric furnace, gas through the heater, flow of gas is slow, heating time is long, with high heating efficiency, heat evenly, small heat loss, to ensure full utilization of energy and greatly reduce the electric power and renewable energy, heater power is accompanied about 60% of other manufacturers. Electric furnace with constant temperature design, the entire regeneration process control at a constant heating temperature range, avoid the damage and loss of power of the electric furnace itself by frequent starting and stopping, effectively reducing the operating costs, extend equipment’s service life.
3. Vessel shell design, manufacture, testing, acceptance according to GB150 <Steel pressure vessels>, and the State Quality and Technical Supervision issued by the <Pressure Vessel Safety Technology supervision order>. Provide a full set of the required documentation of pressure vessels.
4. Original container and furnace design, ensuring smooth gas flow, bed stability, and elimination of damage to the container due to heating or cooling; absorption tower using 16 MnR material, resistant to fatigue, to run at low pressure, the container services for a more longer time.
5. Drying tower configured a filter can effectively remove the particulate component of natural gas , outlet with a fine filter, to prevent secondary pollution caused by adsorbent off, reducing the duplication process pipeline, reducing the pressure drop of equipment, saving the user’s investment cost.
6.This device is equipped with special cabinet, can accurately control the temperature when regenerating the device process, and in accordance with set procedures for movement control regeneration system; control panel set regenerate manual and automatic mode, and manually comes priority. When the regeneration is cycling, it can start or stop the heater, cooler at any time according to actual needs. Control procedures into the work order and interlocking relationships, to avoid human errors caused the losses. Based on the cooling fan, it has set up and down line running between temperature, to ensure the regeneration system does not over-temperature, regenerative heat exchanger does not ice block in winter, and the dew point temperature and dry gas can be observed.
7. For control system, except drying tower, switchover of regeneration tower need manual valve, all other actions will be automatically by the device. When the work tower is adsorbing, output dry gas; when regeneration tower is adsorbing, use a control valve to control the heating temperature of heater, when the regeneration has been finished, heater will automatically stop heating, start doing cold blow, when the temperature inside of the tower blow to the set temperature, the control cabinet will automatically stop all running power system, complete regeneration; all the control parameter can be remodify on controller, flexible and easy.
8. On drying tower device has set pressure gauge, temperature meter, visual display of work pressure and regeneration temperature and other working conditions; drying tower absorption tower has set discharge port with dedicated loading, easy replacement of filling.
9. Drying tower covered with high efficient insulation coating, good effect of insulation, beautiful looking.
10. Electric heating elements are using stainless steel material, thermal conductivity of large area, heating pipe with long service life,ensured that it’s working life will not less than 3 years.
11.Cooler adopts air-cooled efficient plate heat exchanger, it is 2500~4000 M
2
/M
3
higher than surface area. Compared with the same heat transfer area of the tube-fin heat exchanger, the volume was reduced 1.3 times, weight has reduced of more than 1 time.
12. Power generation location of device is reasonable, focus on external connection, produced according DIIBT4 explosion levels.
13.Galvanized pipe through the paint treatment, outdoor installation, long-term use does not fade.
The general technical parameters that can be meet by the deep dehydration device of natural gas
1.Model Low-pressure front, ultra low pressure front, large water content, super flow, high pressure postposition etc.
2. Equipment design working pressure range
3. Maximum handing ability6000Nm
3
/h(1.0mpa)
4. Working environment temperature -30 50°C
5 .Design temperature 345°C
6. Renewable heating temperature 210~230 °C
7. Product gas ordinary pressure dew point ≤-60°C
8.Maximum water content of raw material gas≤3500PPmv
9. Equipment overall pressure drop ≤0.03MPa
10.Adsorbent Molecular sieve
11.Regenerative method Built-in electric furnace, closed loop recycling
12.Cooling-down method Air-cooled or water cooled
13. Number of drying tower 2-4 tower
14.Class of explosive-proof dIIBT4
15. Level of protection IP64
16. Power requirements 380V±7%
17.Electric power around 40% smaller than other similar manufacturers
18.Control method Dedicated control cabinet, manual switching, automatic regeneration, manual discharge
19. Equipment noise ≤70 decibel
20.Measures to Ambient temperature is below 5 prevent ice block 5 °C heating band automatically
21.Fixed mode ship-shaped skid base, without to fix, easy to install
Descriptions of features and performance of equipment
1. Equipment imported the advanced technology from Italy and the United States, novel structure, easy operation, maintenance-free after commissioning. Using the 2 to 4 tower structure for the same equipment, single-stage adsorption, can handle high water content and large flows of feed gas, big quantity of adsorption, long cycle of adsorption, low depth of dehydration, can be operate continuously, continuous output of normal atmospheric dew point lower than -60°C purity, dry gas . Eliminate duplication investment of purchase multiple equipment.
2. The unique closed-loop recycling technology, built-in electric furnace, gas through the heater, flow of gas is slow, heating time is long, with high heating efficiency, heat evenly, small heat loss, to ensure full utilization of energy and greatly reduce the electric power and renewable energy, heater power is accompanied about 60% of other manufacturers. Electric furnace with constant temperature design, the entire regeneration process control at a constant heating temperature range, avoid the damage and loss of power of the electric furnace itself by frequent starting and stopping, effectively reducing the operating costs, extend equipment’s service life.
3. Vessel shell design, manufacture, testing, acceptance according to GB150 <Steel pressure vessels>, and the State Quality and Technical Supervision issued by the <Pressure Vessel Safety Technology supervision order>. Provide a full set of the required documentation of pressure vessels.
4. Original container and furnace design, ensuring smooth gas flow, bed stability, and elimination of damage to the container due to heating or cooling; absorption tower using 16 MnR material, resistant to fatigue, to run at low pressure, the container services for a more longer time.
5. Drying tower configured a filter can effectively remove the particulate component of natural gas , outlet with a fine filter, to prevent secondary pollution caused by adsorbent off, reducing the duplication process pipeline, reducing the pressure drop of equipment, saving the user’s investment cost.
6.This device is equipped with special cabinet, can accurately control the temperature when regenerating the device process, and in accordance with set procedures for movement control regeneration system; control panel set regenerate manual and automatic mode, and manually comes priority. When the regeneration is cycling, it can start or stop the heater, cooler at any time according to actual needs. Control procedures into the work order and interlocking relationships, to avoid human errors caused the losses. Based on the cooling fan, it has set up and down line running between temperature, to ensure the regeneration system does not over-temperature, regenerative heat exchanger does not ice block in winter, and the dew point temperature and dry gas can be observed.
7. For control system, except drying tower, switchover of regeneration tower need manual valve, all other actions will be automatically by the device. When the work tower is adsorbing, output dry gas; when regeneration tower is adsorbing, use a control valve to control the heating temperature of heater, when the regeneration has been finished, heater will automatically stop heating, start doing cold blow, when the temperature inside of the tower blow to the set temperature, the control cabinet will automatically stop all running power system, complete regeneration; all the control parameter can be remodify on controller, flexible and easy.
8. On drying tower device has set pressure gauge, temperature meter, visual display of work pressure and regeneration temperature and other working conditions; drying tower absorption tower has set discharge port with dedicated loading, easy replacement of filling.
9. Drying tower covered with high efficient insulation coating, good effect of insulation, beautiful looking.
10. Electric heating elements are using stainless steel material, thermal conductivity of large area, heating pipe with long service life,ensured that it’s working life will not less than 3 years.
11.Cooler adopts air-cooled efficient plate heat exchanger, it is 2500~4000 M
2
/M
3
higher than surface area. Compared with the same heat transfer area of the tube-fin heat exchanger, the volume was reduced 1.3 times, weight has reduced of more than 1 time.
12. Power generation location of device is reasonable, focus on external connection, produced according DIIBT4 explosion levels.
13.Galvanized pipe through the paint treatment, outdoor installation, long-term use does not fade.
Gas Dehydration Unit
Is especially used for deep dehydration of natural gas in CNG gas filling station
The general technical parameters that can be meet by the deep dehydration device of natural gas
1.Model Low-pressure front, ultra low pressure front, large water content, super flow, high pressure postposition etc.
2. Equipment design working pressure range
3. Maximum handing ability6000Nm
3
/h(1.0mpa)
4. Working environment temperature -30 50°C
5 .Design temperature 345°C
6. Renewable heating temperature 210~230 °C
7. Product gas ordinary pressure dew point ≤-60°C
8.Maximum water content of raw material gas≤3500PPmv
9. Equipment overall pressure drop ≤0.03MPa
10.Adsorbent Molecular sieve
11.Regenerative method Built-in electric furnace, closed loop recycling
12.Cooling-down method Air-cooled or water cooled
13. Number of drying tower 2-4 tower
14.Class of explosive-proof dIIBT4
15. Level of protection IP64
16. Power requirements 380V±7%
17.Electric power around 40% smaller than other similar manufacturers
18.Control method Dedicated control cabinet, manual switching, automatic regeneration, manual discharge
19. Equipment noise ≤70 decibel
20.Measures to Ambient temperature is below 5 prevent ice block 5 °C heating band automatically
21.Fixed mode ship-shaped skid base, without to fix, easy to install
Descriptions of features and performance of equipment
1. Equipment imported the advanced technology from Italy and the United States, novel structure, easy operation, maintenance-free after commissioning. Using the 2 to 4 tower structure for the same equipment, single-stage adsorption, can handle high water content and large flows of feed gas, big quantity of adsorption, long cycle of adsorption, low depth of dehydration, can be operate continuously, continuous output of normal atmospheric dew point lower than -60°C purity, dry gas . Eliminate duplication investment of purchase multiple equipment.
2. The unique closed-loop recycling technology, built-in electric furnace, gas through the heater, flow of gas is slow, heating time is long, with high heating efficiency, heat evenly, small heat loss, to ensure full utilization of energy and greatly reduce the electric power and renewable energy, heater power is accompanied about 60% of other manufacturers. Electric furnace with constant temperature design, the entire regeneration process control at a constant heating temperature range, avoid the damage and loss of power of the electric furnace itself by frequent starting and stopping, effectively reducing the operating costs, extend equipment’s service life.
3. Vessel shell design, manufacture, testing, acceptance according to GB150 <Steel pressure vessels>, and the State Quality and Technical Supervision issued by the <Pressure Vessel Safety Technology supervision order>. Provide a full set of the required documentation of pressure vessels.
4. Original container and furnace design, ensuring smooth gas flow, bed stability, and elimination of damage to the container due to heating or cooling; absorption tower using 16 MnR material, resistant to fatigue, to run at low pressure, the container services for a more longer time.
5. Drying tower configured a filter can effectively remove the particulate component of natural gas , outlet with a fine filter, to prevent secondary pollution caused by adsorbent off, reducing the duplication process pipeline, reducing the pressure drop of equipment, saving the user’s investment cost.
6.This device is equipped with special cabinet, can accurately control the temperature when regenerating the device process, and in accordance with set procedures for movement control regeneration system; control panel set regenerate manual and automatic mode, and manually comes priority. When the regeneration is cycling, it can start or stop the heater, cooler at any time according to actual needs. Control procedures into the work order and interlocking relationships, to avoid human errors caused the losses. Based on the cooling fan, it has set up and down line running between temperature, to ensure the regeneration system does not over-temperature, regenerative heat exchanger does not ice block in winter, and the dew point temperature and dry gas can be observed.
7. For control system, except drying tower, switchover of regeneration tower need manual valve, all other actions will be automatically by the device. When the work tower is adsorbing, output dry gas; when regeneration tower is adsorbing, use a control valve to control the heating temperature of heater, when the regeneration has been finished, heater will automatically stop heating, start doing cold blow, when the temperature inside of the tower blow to the set temperature, the control cabinet will automatically stop all running power system, complete regeneration; all the control parameter can be remodify on controller, flexible and easy.
8. On drying tower device has set pressure gauge, temperature meter, visual display of work pressure and regeneration temperature and other working conditions; drying tower absorption tower has set discharge port with dedicated loading, easy replacement of filling.
9. Drying tower covered with high efficient insulation coating, good effect of insulation, beautiful looking.
10. Electric heating elements are using stainless steel material, thermal conductivity of large area, heating pipe with long service life,ensured that it’s working life will not less than 3 years.
11.Cooler adopts air-cooled efficient plate heat exchanger, it is 2500~4000 M
2
/M
3
higher than surface area. Compared with the same heat transfer area of the tube-fin heat exchanger, the volume was reduced 1.3 times, weight has reduced of more than 1 time.
12. Power generation location of device is reasonable, focus on external connection, produced according DIIBT4 explosion levels.
13.Galvanized pipe through the paint treatment, outdoor installation, long-term use does not fade.
The general technical parameters that can be meet by the deep dehydration device of natural gas
1.Model Low-pressure front, ultra low pressure front, large water content, super flow, high pressure postposition etc.
2. Equipment design working pressure range
3. Maximum handing ability6000Nm
3
/h(1.0mpa)
4. Working environment temperature -30 50°C
5 .Design temperature 345°C
6. Renewable heating temperature 210~230 °C
7. Product gas ordinary pressure dew point ≤-60°C
8.Maximum water content of raw material gas≤3500PPmv
9. Equipment overall pressure drop ≤0.03MPa
10.Adsorbent Molecular sieve
11.Regenerative method Built-in electric furnace, closed loop recycling
12.Cooling-down method Air-cooled or water cooled
13. Number of drying tower 2-4 tower
14.Class of explosive-proof dIIBT4
15. Level of protection IP64
16. Power requirements 380V±7%
17.Electric power around 40% smaller than other similar manufacturers
18.Control method Dedicated control cabinet, manual switching, automatic regeneration, manual discharge
19. Equipment noise ≤70 decibel
20.Measures to Ambient temperature is below 5 prevent ice block 5 °C heating band automatically
21.Fixed mode ship-shaped skid base, without to fix, easy to install
Descriptions of features and performance of equipment
1. Equipment imported the advanced technology from Italy and the United States, novel structure, easy operation, maintenance-free after commissioning. Using the 2 to 4 tower structure for the same equipment, single-stage adsorption, can handle high water content and large flows of feed gas, big quantity of adsorption, long cycle of adsorption, low depth of dehydration, can be operate continuously, continuous output of normal atmospheric dew point lower than -60°C purity, dry gas . Eliminate duplication investment of purchase multiple equipment.
2. The unique closed-loop recycling technology, built-in electric furnace, gas through the heater, flow of gas is slow, heating time is long, with high heating efficiency, heat evenly, small heat loss, to ensure full utilization of energy and greatly reduce the electric power and renewable energy, heater power is accompanied about 60% of other manufacturers. Electric furnace with constant temperature design, the entire regeneration process control at a constant heating temperature range, avoid the damage and loss of power of the electric furnace itself by frequent starting and stopping, effectively reducing the operating costs, extend equipment’s service life.
3. Vessel shell design, manufacture, testing, acceptance according to GB150 <Steel pressure vessels>, and the State Quality and Technical Supervision issued by the <Pressure Vessel Safety Technology supervision order>. Provide a full set of the required documentation of pressure vessels.
4. Original container and furnace design, ensuring smooth gas flow, bed stability, and elimination of damage to the container due to heating or cooling; absorption tower using 16 MnR material, resistant to fatigue, to run at low pressure, the container services for a more longer time.
5. Drying tower configured a filter can effectively remove the particulate component of natural gas , outlet with a fine filter, to prevent secondary pollution caused by adsorbent off, reducing the duplication process pipeline, reducing the pressure drop of equipment, saving the user’s investment cost.
6.This device is equipped with special cabinet, can accurately control the temperature when regenerating the device process, and in accordance with set procedures for movement control regeneration system; control panel set regenerate manual and automatic mode, and manually comes priority. When the regeneration is cycling, it can start or stop the heater, cooler at any time according to actual needs. Control procedures into the work order and interlocking relationships, to avoid human errors caused the losses. Based on the cooling fan, it has set up and down line running between temperature, to ensure the regeneration system does not over-temperature, regenerative heat exchanger does not ice block in winter, and the dew point temperature and dry gas can be observed.
7. For control system, except drying tower, switchover of regeneration tower need manual valve, all other actions will be automatically by the device. When the work tower is adsorbing, output dry gas; when regeneration tower is adsorbing, use a control valve to control the heating temperature of heater, when the regeneration has been finished, heater will automatically stop heating, start doing cold blow, when the temperature inside of the tower blow to the set temperature, the control cabinet will automatically stop all running power system, complete regeneration; all the control parameter can be remodify on controller, flexible and easy.
8. On drying tower device has set pressure gauge, temperature meter, visual display of work pressure and regeneration temperature and other working conditions; drying tower absorption tower has set discharge port with dedicated loading, easy replacement of filling.
9. Drying tower covered with high efficient insulation coating, good effect of insulation, beautiful looking.
10. Electric heating elements are using stainless steel material, thermal conductivity of large area, heating pipe with long service life,ensured that it’s working life will not less than 3 years.
11.Cooler adopts air-cooled efficient plate heat exchanger, it is 2500~4000 M
2
/M
3
higher than surface area. Compared with the same heat transfer area of the tube-fin heat exchanger, the volume was reduced 1.3 times, weight has reduced of more than 1 time.
12. Power generation location of device is reasonable, focus on external connection, produced according DIIBT4 explosion levels.
13.Galvanized pipe through the paint treatment, outdoor installation, long-term use does not fade.
Gas Regulating metering System
Natural Gas Pressure regulating station
Gas metering station
SCADA system
Natural Gas Pressure Regulating Station,Gas pressure reducing & metering station
We design and manufacture the following plants:
* High Pressure City Gate and Offtake station;
* High-medium pressure Reducing & Metering Station;
* Low pressure Reducing & Metering Cabinet;
* Compressed natural gas reducing stations;
* Two-stage domestic reducing cabinet ;
* SCADA systems.
and following standard products:
* Turbine meter;
* Butterfly valve;
* Ball valve;
* Safety devices;
* Pressure regulator;
* Control valves;
* Other components.
Capacity of
completed
Natural Gas Pressure Regulating Station
Flow rate: 6000Sm3/h-160,000Sm3/h
Max Inlet pressure MPA:3.6
Min. Outlet pressure KPA:100
Application:
City gate station,long pipelines,power plant,oil field gas fuel power plant,gas turbine power plant etc.
Gas metering station
SCADA system
Natural Gas Pressure Regulating Station,Gas pressure reducing & metering station
We design and manufacture the following plants:
* High Pressure City Gate and Offtake station;
* High-medium pressure Reducing & Metering Station;
* Low pressure Reducing & Metering Cabinet;
* Compressed natural gas reducing stations;
* Two-stage domestic reducing cabinet ;
* SCADA systems.
and following standard products:
* Turbine meter;
* Butterfly valve;
* Ball valve;
* Safety devices;
* Pressure regulator;
* Control valves;
* Other components.
Capacity of
completed
Natural Gas Pressure Regulating Station
Flow rate: 6000Sm3/h-160,000Sm3/h
Max Inlet pressure MPA:3.6
Min. Outlet pressure KPA:100
Application:
City gate station,long pipelines,power plant,oil field gas fuel power plant,gas turbine power plant etc.
Gas Spherical Tanks
Customized model for Natural Gas Storage, for Pak industries keeping in consideration the current situation of Energy Shortage.
Specification
Wall thickness of Spherical shell plates
From 12mm to 62mm
Minimum Temperature
-50°C
Maximum single size
Width 3,650mm, length 12,580mm
Medium
Ethylene, Propylene, Oxygen, Nitrogen, Ammonia, Vinyl Chloride, natural gas, argon, Hydrogen, Liquefied Gas, LPG, LNG, Coal Gas, Water Gas, Compressed Air, Vacuum, Liquid Ammonia, Liquid Nitrogen, Refined Propylene, Butadiene, Isobutene, Propane, C3 Fraction, C4, C5, VCM, Clean Oil, Liquid Methyl Ether, Liquid Carbon Dioxide, Pulverized Coal, Light Hydrocarbon, methyl chloride, etc.
Cubage Dimension
From 50m³ to 10000m³
Note:
OEM service, provide all kinds of specifications and models of spherical tank according to customers requirements
Specification
Wall thickness of Spherical shell plates
From 12mm to 62mm
Minimum Temperature
-50°C
Maximum single size
Width 3,650mm, length 12,580mm
Medium
Ethylene, Propylene, Oxygen, Nitrogen, Ammonia, Vinyl Chloride, natural gas, argon, Hydrogen, Liquefied Gas, LPG, LNG, Coal Gas, Water Gas, Compressed Air, Vacuum, Liquid Ammonia, Liquid Nitrogen, Refined Propylene, Butadiene, Isobutene, Propane, C3 Fraction, C4, C5, VCM, Clean Oil, Liquid Methyl Ether, Liquid Carbon Dioxide, Pulverized Coal, Light Hydrocarbon, methyl chloride, etc.
Cubage Dimension
From 50m³ to 10000m³
Note:
OEM service, provide all kinds of specifications and models of spherical tank according to customers requirements
Subscribe to:
Posts (Atom)